Categories

ATEN 20A/16A 30-Outlet 3-Phase Outlet-Metered & Switched eco PDU

Part No:

PG98230G

exc VAT
£0.00
£0.00
inc VAT
Save 5% - First order discount - Any product - Any price*
Use Promo Code: FIRST5
*This promotion may only be used once, 5% discount is applied to your first order. Can not be used in-conjunction with any other offers. Not available if paying with PayPal.

This item is currently unavailable for next day delivery, however you may still order this item as a back-order?.

16A 30-Outlet 3PH Outl-Met & Switch

Non-Returnable*

*This item is non-returnable and non-cancellable due to customisation or built to order.

Request info below or give us a call on 0203 617 7663
SKU: PG98230G Category:

Can't find what your looking for?

Our qualified I.T. experts are here & ready to help.

Contact us on 0203 617 7663 or email us directly

Description

When maintaining operating uptime in a data center or server room, sustainable energy efficiency can make all the difference. The implementation of effective power management often involves improvements at both the hardware and software level. As the trend for 3-phase power grows due to its efficiency to generate, transfer, and distribute electricity, ATEN is introducing its latest PG series of PDUs, available in IEC socket configuration, that are designed with 0U rack housing to accommodate the increasing demand for power to high-density IT equipment in server rooms and data centers. Each PG98230 PDU, utilizing an ARM-Cortex A8 processor, is equipped with 30 port outlets capable of running at higher voltages, powers up all connected equipment in less than 10 seconds once plugged in, and delivers the most accurate kWh energy usage data (+/-1%) for better power consumption habits, baselines, and initiative tracking. With energy saving in mind, the PG98230 is purposed to enable lower energy consumption for best practice in a network infrastructure, while promoting up to 70.65 kg (131.4 kw equivalent of power consumption) of reduced CO2 emission, reduced electricity expenses, and lower carbon taxes to pay each year.

Energy-Saving Relay
Thanks to the built-in energy-saving relays – a subtype of electromagnetic switch – controlling a large amount of current flow becomes easy, which results in annual saving of 131.4 kW power consumption per 30-outlet PDU unit, compared with models without energy-saving relays. In addition, power distribution will remain functional and uninterrupted even when a failure occurs, enabling superior uptime to optimize system reliability.

Secure Locking Enhancement
The outlets can be protected with a secure lock to prevent power cords from becoming unplugged due to vibration or human errors.

Real-time Alerts via LCD Display
The illuminated LCD display can display warnings to alert users of unusual power states.

Hot-Swappable Function
The LCD console panel is hot-swappable and can be removed, replaced, or repaired without powering down a mission-critical connected load.

Dual LAN Ports for Scalable Network Setup
The PG98230 is equipped with dual LAN ports (e.g. Internet and Intranet) supporting up to 1G Ethernet connection, and can be cascaded to connect up to 64 PDUs, saving expense on installing extra network switches to incorporate network connections while sparing more rack space to accommodate more IT equipment in an expandable network.

Environment Sensors
The Sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats.

Flexible On-Site Network Operation
For quick operation, connecting a serial device to the PDU with its COM port provides another means to undertake communication via CLI commands. In addition, the same port is also functional as a PON port, available for Ethernet connection to a KN series KVM over IP Switch to centralize power management of up to 16 daisy-chained PDUs.

Networkable via WiFi
The PG98230 can be networked via connection to a USB WiFi dongle to perform DCIM, firmware upgrade, log export, quick configuration, and more.

Adjustable Power Cord for Flexible In-Rack Installation
The PG98230 comes with an adjustable power cord built in to the unit capable of 90-degree rotation to allow flexible in-rack installation, resulting in better cable organization.

DCIM Monitoring
Integrated with ATEN’s eco DC – a PC- and web-based tool for optimized Data Center Infrastructure Management (DCIM) – power distribution, energy, and environmental data from PDUs and connected devices can be monitored via a friendly web GUI for smart power management.

Colored Panel for Smarter Power Monitoring
The PG series PDUs feature a LCD console panel in default red and can be re-colored with options of yellow, purple, blue, and green through optional purchase of colored stickers. These color codes make it easier to differentiate between power feed settings and also speed up troubleshooting in case of unexpected failures.

Applications
The PG series 3-Phase PDUs are perfectly suited to server rack installation requiring energy-efficient power distribution to high-density IT equipment in a server room or data center.


Feature Feature Value
PDU types Metered, Switched
Rack capacity 0U
Type Three-phase
Product colour Black
Display LCD
AC outlets quantity 30 AC outlet(s)
AC outlet types C13 coupler, C19 coupler
Power plug IEC309
Serial ports quantity 2
Ethernet LAN (RJ-45) ports 2
USB ports quantity 1
Daisy chain Yes
Reset button Yes
Cable length 3 m
Security algorithms SMTP-AUTH, TLS
Certification EMC
Monitoring Current, Power, Voltage
Supported network protocols TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet, Modbus (over TCP/IP), Wi-Fi, 802.11 a/b/g/n, IPv6, SMS
Firmware upgradeable Yes
Firmware upgradeable via Network
Nominal input voltage 230 – 400 V
Maximum current 16 A
AC input frequency 50 – 60 Hz
Nominal output voltage 230 V
Load capacity 11084 VA
Circuit breaker No
Width 56 mm
Depth 1790 mm
Height 68 mm
Weight 7.36 kg
Package weight 10.2 kg
Package width 229 mm
Package depth 1945 mm
Package height 179 mm
Package volume 79853.5 cm³
Manual Yes
Rack mount kit Yes
Operating temperature (T-T) 0 – 60 °C
Storage temperature (T-T) -20 – 60 °C
Operating relative humidity (H-H) 0 – 80%
Sustainability compliance Yes
Sustainability certificates CE
Country of origin Taiwan
Master (outer) case net weight 7.51 kg
Master (outer) case width 229 mm
Master (outer) case length 1945 mm
Master (outer) case height 179 mm
Master (outer) case gross weight 10.2 kg
Master (outer) case volume 79853.5 cm³

Additional information

PDU types

Metered, Switched

Type

Three-phase

Display

LCD

AC outlet types

C13 coupler, C19 coupler

Serial ports quantity

2

USB ports quantity

1

Reset button

Yes

Security algorithms

SMTP-AUTH, TLS

Monitoring

Current, Power, Voltage

Firmware upgradeable

Yes

Nominal input voltage

230-400 V

AC input frequency

50/60 Hz

Load capacity

11084 VA

Width

56 mm

Height

68 mm

Package weight

10.2 kg

Package depth

1945 mm

Package volume

79853.5 cm³

Rack mount kit

Yes

Storage temperature (T-T)

-20 – 60 °C

Sustainability compliance

Yes

Country of origin

Taiwan

Master (outer) case width

229 mm

Master (outer) case height

179 mm

Master (outer) case volume

79853.5 cm³

Rack capacity

0U

Product colour

Black

AC outlets quantity

30 AC outlet(s)

Power plug

IEC309

Ethernet LAN (RJ-45) ports

2

Daisy chain

Yes

Cable length

3 m

Certification

EMC

Supported network protocols

TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet, Modbus (over TCP/IP), Wi-Fi, 802.11 a/b/g/n, IPv6, SMS

Firmware upgradeable via

Network

Maximum current

16 A

Nominal output voltage

230 V

Circuit breaker

No

Depth

1790 mm

Weight

7.36 kg

Package width

229 mm

Package height

179 mm

Manual

Yes

Operating temperature (T-T)

0 – 60 °C

Sustainability certificates

CE

Master (outer) case length

1945 mm

Brand

Aten