Categories

APC SRVPM10KRIL uninterruptible power supply (UPS) Double-conversion (Online) 10

Part No:
SRVPM10KRIL
exc VAT
£4,238.09
£5,085.71
inc VAT
Save 5% - First order discount - Any product - Any price*
Use Promo Code: FIRST5
*This promotion may only be used once, 5% discount is applied to your first order. Can not be used in-conjunction with any other offers. Not available if paying with PayPal.

This item is currently unavailable for next day delivery, however you may still order this item as a back-order?

APC Easy UPS SRV RM 10000VA 230V No Battery Extended Runtime

Available on back-order

Non-Returnable*

Safe & Secure shopping

*This item is non-returnable and non-cancellable due to customisation or built to order.

SKU: SRVPM10KRIL Category:

Can't find what your looking for?

Our qualified I.T. experts are here & ready to help.

Contact us on 0203 617 7663 or email us directly

Description

Automatic internal bypass

Pure static bypass switch without bridging contactor securing a fast and reliable transfer to and from bypass, rated for 125% nominal load.

Automatic restart of loads after UPS shutdown

Automatically starts up the connected equipment upon the return of utility power.

ECO Mode

Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection

EPO

Attach the device to an Emergency Power Off (EPO) system so that power can be turned off in an emergency situation.

Input power factor correction

Minimizes installation costs by enabling the use of smaller generators and cabling.

Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Intelligent Card Slot

Customize UPS capabilities with management cards.

LCD graphics display

Text and mimic diagrams that display modes of operation, system parameters and alarms.

Serial connectivity

Provides management of the UPS via a serial port.

USB connectivity

Provides management of the UPS via a USB port (not available on all models).

Serial connectivity

Provides management of the UPS via a serial port.

LED status indicators

Quickly understand unit and power status with visual indicators.

Network manageable

Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.

InfraStruXure Manager Compatible

Enables centralized management via the APC InfraStruXure Manager.

Intelligent Card Slot

Customize UPS capabilities with management cards.

Avoids costly power problems by keeping your IT equipment and data protected and available .

Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.

Save time with easy and convenient remote/network accessibility.

Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.

Low operating and maintenance costs with proven reliability and intelligent battery management .

Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.

Peace of mind that comes with full equipment compatibility and reliability of a leader

Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.

Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Power conditioning

Protects connected loads from surges, spikes, lightning, and other power disturbances.

Resettable circuit breaker

Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)

Generator compatible

Ensures clean, uninterrupted power to protected equipment when generator power is used.

Input power factor correction

Minimizes installation costs by enabling the use of smaller generators and cabling.

Cold-start capable

Provides temporary battery power when the utility power is out.

Frequency and voltage regulation

Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Disconnected battery notification

Warns when a battery is not available to provide backup power.

Audible alarms

Provides notification of changing utility power and UPS power conditions

Predictive failure notification.

Provides early-warning fault analysis ensuring proactive component replacement.

User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing
Mean Time to Repair (MTTR)

Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Rack/Tower convertible

Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

Flash upgradeable firmware

Install maintenance releases of firmware remotely using FTP.

Plug-and-Play external batteries

Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

Automatic internal bypass

Supplies utility power to the connected loads in the event of a UPS power overload or fault.

Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Scalable runtime

Allows additional run time to be quickly added as needed.

Automatic restart of loads after UPS shutdown

Automatically starts up the connected equipment upon the return of utility power.

Temperature-compensated battery charging

Prolongs battery life by regulating the charge voltage according to battery temperature.

Hot-swappable batteries

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced


Feature Feature Value
UPS topology Double-conversion (Online)
Output power capacity 10 kVA
Output power 10000 W
Waveform Sine
Input operation voltage (min) 110 V
Input operation voltage (max) 300 V
Input frequency 40/70 Hz
Output operation voltage (min) 220 V
Output operation voltage (max) 240 V
Surge energy rating 600 J
Crest factor 3:1
ECO mode Yes
Emergency Power Off (EPO) Yes
Noise level 58 dB
Audible alarm(s) Yes
Audible alarm modes Alarm when on battery, Low battery alarm, Overload alarm
Auto-restart Yes
USB port Yes
Serial interface Yes
SmartSlot Yes
Battery technology Sealed Lead Acid (VRLA)
Battery voltage 240 V
Hot-swap battery Yes
Automatic battery test Yes
Cold start Yes
Form factor Rackmount/Tower
Product colour Black
Display type LCD
LED indicators Yes
Operating temperature (T-T) 0 – 40 °C
Operating relative humidity (H-H) 0 – 95%
Storage relative humidity (H-H) 0 – 95%
Operating altitude 0 – 3000 m
Non-operating altitude 0 – 15000 m
Certification CE, EAC, EN/IEC 62040-1, EN/IEC 62040-2
Cables included USB cable
Manual Yes
Width 438 mm
Depth 615 mm
Height 87 mm
Weight 16 kg
Package width 600 mm
Package depth 760 mm
Package height 240 mm
Package weight 20 kg
Harmonized System (HS) code 85078000

Additional information

UPS topology

Double-conversion (Online)

Output power

10000 W

Input frequency

40/70 Hz

Crest factor

3:1

Emergency Power Off (EPO)

Yes

Audible alarm(s)

Yes

Auto-restart

Yes

Serial interface

Yes

Battery technology

Sealed Lead Acid (VRLA)

Hot-swap battery

Yes

Cold start

Yes

Product colour

Black

LED indicators

Yes

Operating altitude

0 – 3000 m

Certification

CE, EAC, EN/IEC 62040-1, EN/IEC 62040-2

Manual

Yes

Depth

615 mm

Weight

16 kg

Package depth

760 mm

Package weight

20 kg

Output power capacity

10 kVA

Waveform

Sine

Surge energy rating

600 J

ECO mode

Yes

Noise level

58 dB

Audible alarm modes

Alarm when on battery, Low battery alarm, Overload alarm

USB port

Yes

SmartSlot

Yes

Battery voltage

240 V

Automatic battery test

Yes

Form factor

Rackmount/Tower

Display type

LCD

Operating temperature (T-T)

0 – 40 °C

Non-operating altitude

0 – 15000 m

Cables included

USB cable

Width

438 mm

Height

87 mm

Package width

600 mm

Package height

240 mm

Harmonized System (HS) code

85078000

Brand

APC