Categories

APC AP7911B power distribution unit (PDU) 16 AC outlet(

Part No:
AP7911B
exc VAT
£0.00
£0.00
inc VAT
Save 5% - First order discount - Any product - Any price*
Use Promo Code: FIRST5
*This promotion may only be used once, 5% discount is applied to your first order. Can not be used in-conjunction with any other offers.

This item is currently unavailable for next day delivery, however you may still order this item as a back-order?

'

APC Switched Rack PDU AP7911B – Power distribution strip (rack-mountable) – AC 208 V – Ethernet 10/100 – input: NEMA L6-30 – output connectors: 16 (power IEC 60320 C13) – 2U – 3.65 m cord – black – for P/N: SMTL1000RMI2UC, SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC

Request info below or give us a call on 0203 617 7663
SKU: AP7911B Category:

Can't find what your looking for?

Our qualified I.T. experts are here & ready to help.

Contact us on 0203 617 7663 or email us directly

Description

Availability

Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Marketing Features

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Agility

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most – in the racks near the equipment.

Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.


Feature Feature Value
PDU types Switched
Rack capacity 2U
Product colour Black
AC outlets quantity 16 AC outlet(s)
AC outlet types C13 coupler
Input connection type NEMA L6-30P
LED indicators Yes
Cable length 3.66 m
Certification cUL, CSA, FCC 15 A, ICES-003, PSE, UL 60950, UL
Monitoring Current
Outlet control Recycle, Turn off
Nominal input voltage 200-230 V
Maximum current 30 A
AC input frequency 50 – 60 Hz
Maximum input current per phase 30 A
Maximum total current draw per phase 30 A
Dimensions (WxDxH) 444 x 254 x 89 mm
Weight 6.32 kg
Package dimensions (WxDxH) 514 x 514 x 146 mm
Package weight 8.36 kg
Operating temperature (T-T) 0 – 45 °C
Storage temperature (T-T) -25 – 65 °C
Operating relative humidity (H-H) 0 – 95%
Storage relative humidity (H-H) 0 – 95%
Operating altitude 0 – 3000 m
Non-operating altitude 0 – 15000 m
Sustainability certificates RoHS

Additional information

PDU types

Switched

Product colour

Black

AC outlet types

C13 coupler

LED indicators

Yes

Certification

cUL, CSA, FCC 15 A, ICES-003, PSE, UL 60950, UL

Outlet control

Recycle, Turn off

Maximum current

30 A

Dimensions (WxDxH)

444 x 254 x 89 mm

Package dimensions (WxDxH)

514 x 514 x 146 mm

Operating temperature (T-T)

0 – 45 °C

Operating altitude

0 – 3000 m

Sustainability certificates

RoHS

Rack capacity

2U

AC outlets quantity

16 AC outlet(s)

Input connection type

NEMA L6-30P

Cable length

3.66 m

Monitoring

Current

Nominal input voltage

200-230 V

AC input frequency

50/60 Hz

Weight

6.32 kg

Package weight

8.36 kg

Storage temperature (T-T)

-25 – 65 °C

Non-operating altitude

0 – 15000 m

Brand